Electromagnetic Feeder - 26C Model

26C Electromagnetic Feeder

26Cfeeder.jpg

 

Electromagnetic Feeder - 26C Model

FOR FEEDING UP TO 4 TONS (3.6 MT) PER HOUR

A rugged AC-operated unit for linear, accurate feeding of large quantities of bulk materials such as akes, lumps and grains.

Features & Benefts:

  • Electro-permanent magnet drive
  • AC operation of most models
  • Standard and custom trays
  • Enclosed drive element
  • Low power consumption
  • Class II hazardous location drives available
  • Available for washdown application
  • High amplitude/low frequency available
  • Available to USDA requirements with CE and CSA approved models
  • Solid-state controls

Hi-Vi Electromagnetic

Eriez’ unique Hi-Vi magnetic drive circuit provides a simple yet powerful solution to dif cult material feeding applications. These feeders, with their totally enclosed patented magnetic drive, can feed practically any bulk material from micron size to bulky chunks. Solid-state controls operate the feeders with “watch– like” precision. In addition, you get all the features that for years have made Eriez Feeders the leaders in quality and dependability. Eriez has standard models for the majority of feeding applications. Special units such as multiple drives, enclosed trays or screens can be designed for the best solution to your application. In addition, a wide variety of standard and special trays are available.

Electro–Permanent Magnetic Drive

The basic simplicity of a drive powered by alternately opposing and attracting magnetic forces assures low maintenance. There are no sliding or rotating parts. Power consumption is low, installation easy. The positive driving force of Eriez units provides stability, control, and unexcelled accuracy.

AC Operation For Most Models

No rectifiers are required; feeders are simply wired into AC lines.

Simple Controls

Eriez electromagnetic feeder controls are reliable, state-of-the- art, solid-state units that deliver superior feed rate control. By varying the voltage to the feeder, coupled with Eriez AC circuit, excellent linearity is acheived. Standard controls come in NEMA 12 (IP54) enclosures. Special enclosures are also available. Controls can be provided with manual or automatic (analog signal) adjustment to address many applications. Special design controls are also available to address your unique requirements.

Encapsulation

The coil and magnet in Eriez’ drive unit are encapsulated in epoxy, eliminating coil movement and thus extending trouble – free coil life.

Enclosed Drive Element

The completely enclosed drive element, dust and moisture resistant, extends coil life and makes external cleaning easier. Special enclosures are available for dusty locations where Class II, Group F and G equipment is normally used.

High Temperature Units

Standard units operate at temperatures up to 130°F (54°C). High–temperature units are available for temperatures up to 300°F (150°C).

The Patented Eriez Hi–Vi Magnetic Drive Circuit

Prior to Eriez revolutionary AC design, electromagnetic vibratory equipment operated with an inef cient attract release system: a spring – mounted moving mass is alternately attracted by a rectified pulsating DC electromagnet and returned to its original position solely by the springs. The Eriez HI-VI system, on the other hand, incorporates a lifetime permanent magnet (part of a spring–mounted moving mass) whose poles are intermeshed with those of an electromagnet powered directly by an AC line. This results in the spring- mounted moving mass being both attracted and repelled by the AC electromagnet equally on each half of the AC cycle.

In the diagram below, the poles of the permanent magnet are shown intermeshed in the air gaps of the AC electromagnet. The polarity of the permanent magnet is xed, while the polarity of the electromagnet alternates at line frequency. The electromagnet polarity is shown as it exists on one side of the AC sine wave; note that both poles of the permanent magnet are attracted toward the unlike electromagnet poles while being repelled in the same direction by the like poles. Thus there are four forces acting together to drive the armature and moving mass in the same direction.

The action described has the effect of progressively closing the magnetizing circuit through the electromagnet core, providing a progressively increasing magnetizing force upon the permanent magnet. The demagnetizing force is very minor, since the action described also has the effect of progressively opening the demagnetizing circuit.

On the opposite side of the sine wave the polarities of the electromagnet are reversed, the armature is driven in the opposite direction, and again there is a net magnetizing force on the permanent magnet. There is always a predominant magnetizing force impressed upon the permanent magnet that prevents it from ever losing its strength.

Since the amplitude of vibration depends directly upon the forces applied at the poles, and since these forces depend directly upon the applied AC voltage, simple variation of the AC voltage from zero to maximum results in similar amplitude variation from zero to maximum.
 

Product Table

Item Name Part Number Description
Model 26C Feeder System 13148620/44559807E MODEL 26C with 5x22 S.S. tray w/ N12 UN/115-2A-FW-NSF controller.

 

NOTE: Other tray sizes available. Consult Eriez for pricing.

 

For technical assistance, more information or a request for quote, please complete this form.

RFQ Form

 

X
 
ERIEZ
Headquarters | 2200 Asbury Road | Erie, PA 16506
814.835.6000 | 800.345.4946