Problem:
Fine iron particles were somehow being introduced into the process where graphite was being prepared for shipment.
Solution:
An Eriez Volumatic Feeder was used to store, then transport the contaminated graphite to an Eriez High Intensity Magnetic Separator.
Particles embedded with iron were separated from the material flow.